Posts: 74 Threads: 18. Joined: May 2018. 1 11-16-2018, 11:12 PM. Hello Everyone. I have a DD15 with white smoke coming out of the exhaust during regeneration. I have already replaced injectors and it does not waste antifreeze freon. I would like to know if anyone can tell me What else might be the cause or what else could it possibly be.From the very beginning, the Cascadia ® was built to be an industry benchmark – a truck that expands our approach to lowering your Real Cost of Ownership SM (RCO) while emphasizing the key role of professional truck drivers. Base Specifications. Class. 8. Horsepower.Quick instructions on how to regen on a Freightliner. 1. Cruise control Off2. Press and hold regen button 3. Wait for it to finish#owneroperator #trucking #h...How to regen a 2018 Freightliner Cascadia

hello everyone, 2013 freightliner cascadia dd13, ok had the def deleted truck runs great no more derate. but my truck still goes in regen after 3.5 mins after 29-30 mins it stops. i still have th e yellow check engine light that shows. was wondering if anyone could lend a few mins. to let me know what might be happening.Paypal https://paypal.me/dirtydieselmechanic...My favorite FLASHLIGHT https://amzn.to/3CXQNAOE-Torx Star Socket Sethttps://amzn.to/2NSehiYDEWALT 20V MAX Cord...DTF delivers flexible and customized financing solutions for owner-operators, as well as vocational and fleet customers. Available Financing. The Cascadia natural gas delivers near-zero emissions and with its advanced aerodynamic design is both fuel efficient and environmentally friendly.

I am working on a 2019 Freightliner Cascadia with a DD13, and it is locked into a 5mph derate. I am using the Detroit Diagnostic Link 8 software. ... The injector balance is under 3, it idles smooth, but when it comes up to temp starting the regen it starts running rough. It's still in regen mode, but the current step says waiting on DPF outlet ...Freightliner Cascadia,Volvo, Peterbilt,KENWORTH,Semi trucks,repairs,regen,etc.

I started with a new company and leased a 2020 Cascadia. Truck did not come with an APU and I can't afford one right now. It will idle fine. ... Discussion in 'Freightliner Forum' started by DeadOnTime, Mar 8, 2019. Page 1 of 3 1 2 3 Next > Mar 8, 2019 #1. ... I've been told that idling too much will just mean I need to regen more often. I have ...2020 freightliner Cascadia. Detroit DD15 motor. 3 months ago the freightliner dealer cleaned the DPF when an injector was replaced so probably not the issue. Recently it had a full derate due to regen … read moreDownload freightliner cascadia service workshop manual - workshopFreightliner cascadia troubleshooting manual pdf Freightliner cascadia. manualFreightliner cascadia diagram instrument cluster dash m2 wiring lights light dashboard meanings key fault board control flashing regen codes menu.Four Star Freightliner diesel technician Jason Scroggins explains the process of how to do a parked regen for your truck. This process is for any Freightline...Generally if you're a long haul truck driver, roughly about every 4-7 days is a sign of a healthy exhaust aftertreatment system. Local truck drivers should generally need a regen about every 7 days or more possibly. Again this also depends on how often your truck or if it does at all do highway regens.

When this happens, a driver has to pull over and initiate a self-cleaning process that can take up to 40 minutes — valuable time that could have been spent on the road. But forced regens don't ...

1. Turn cruise off2. Press and hold regen button until process begins (engine RPM will slightly increase)3. Wait (25-45 minutes)Socials:TikTokhttps://www.tik...

2014 Freightliner Cascadia DD15 Turbo return line seal and gasket replaced. Mine was leaking were it goes back into the engine block, o-ring was super hard a...About Press Copyright Contact us Creators Advertise Developers Terms Privacy Policy & Safety How YouTube works Test new features NFL Sunday Ticket Press Copyright ...Parked Regen for 2020 Freightliner CascadiaHow to do a parked regen on a 2021 Freightliner Cascadia. tapq. 2.38K subscribers. Subscribed. 177. 49K views 3 years ago. How to do a parked regen on a 2021 Freightliner Cascadia....Jun 15, 2022 ... Comments ; How to Regen for Freightliner and Volvo trucks. Combined Transport · 235K views ; How we change DPF Filters on 2018 Freightliner ...Title: ISB 6.7 Frequent Regeneration Applies To: IC Bus, MV, DuraStar with ISB or B6.7 CHANGE LOG Please refer to the change log text box below for recent changes to this article: 11/27/2019 - Added DuraStar and MV and image of seal inspection area. 07/10/2019 - Updated author for feedback purposes. 01/25/2019 - Updated author coding

6. Select "Start" on the panel and then engage the regen switch on dash (or through ICUC on New Cascadias). Note: When navigating through the instrument cluster menu on the New Cascadia, follow the prompts which may require you to select the "OK" button twice.Hi I'm having some major problems with 2012 Cascadia its been a nightmare truck. It has a low NOx conversion efficiency and bad quality DEF. The NOx outlet sensor have been charged and brand new DEF pump replaced.The dosers cleaned and inspected air supply checked,voltages check all of the wiring inspected.Doser fuel line is pressure is around 52psi. Fuel doser injection status first starts around 90 to 100 %. Then after about 15 minutes into regen drops down to about 9% and stays around there. The temperatures are around 900 degrees but then drops to about 700 after the doser drops. Dpf inlet pressure is about .5 and outlet about .07. I could not find any videos to do this on my 2015 Freightliner Cascadia. I decided to put this up so that,1. I can remember how to do it later and 2. Maybe ... 106. 48. Feb 6, 2016. 0. 2011 cascadia dd15 and keep getting def quality and scr nox sensor low, codes. The def light starts blinking and slight derate. Codes are eec 61 Spn 4364 fail 18 and eec 61 Spn 3364 fail 02. I started having problems at the beginning of my trip but did a parked Regen and that got me 340 miles.Quick instructions on how to regen on a Freightliner. 1. Cruise control Off2. Press and hold regen button 3. Wait for it to finish#owneroperator #trucking #h...Your truck just got to jump and now all of a sudden your lights are flashing and your hazard lights are not on... most likely this is the number to fuse from...

the check engine light came on, along with the MIL- both amber. Dash codes were 12, 13, 15, 16. Seemed odd that all codes were high and low voltages at once. Truck asked for a regen and the regen light blinking- performed parked regen- lasted about 10mins but never saw temperature increase. Regen light stayed blinking for a day.I have a 2015 freightliner cascadia with a dd15 engine. I just had the egr cooler replaced. I am trying to run a forced regen with Diagnostic 8 and the temp gets up to about 700 before the doers disab … read more

The Smart Source app helps drivers stay connected with Freightliner for up-to-date product news, training videos and support information. An updated app version (v3.0) is now available on Google Play and Apple App Store and provides the following new features: Design Updates - App updated with several design enhancements for improved ease of ...Regeneration is all about removing the particulate matter, or unburnt fuel (aka soot), from the diesel engine exhaust. It's a normal and necessary part of reducing harmful emissions in order to comply with EPA-mandated Tier 4 regulations. Regeneration is the process of incinerating the soot that has collected in the soot filter.Freightliner Cascadia Regen. If your Freightliner has a DPF, you might want to consider getting a regen system. This system is a crucial part of your truck's emissions-control system. A parked regeneration is a simple process that cleans the DPF while the truck is stationary. If you have a manual transmission, you can shift it out of neutral ...I have a 2014 Freightliner Cascadia DD13 VIN6 (FZ2068) that has been derating 25% for SPN-102 FMI 18 Engine Intake Manifold #1 Pressure Engine 2 and now it is shutting down completely with some added ... Ran regen and passed scr efficiency.Welcome to TruckTube!!! On our channel we upload daily, our original, short (2-4min), walkaround videos of Heavy Trucks, Light Trucks, Tractor Trailers, Buss...Don't forget to Subscribe! - https://goo.gl/XtV9CJCheck out our Merch! - https://thedieseler.myteespring.co/Support these videos on Patreon! - https://www.pa...WARNING!!: ⚠️⚠️⚠️Always use the proper tools and safety equipment to perform this job. Failure to perform the job correctly can result in personal injury or ...

Code 1636 is super common. You might have other codes, but if you have 1636 then it is most likely the source of the problem for all those codes. Your truck ...

18 Manual Transmissions and Clutch. 19 Drive Axles. 20 Fifth Wheels. 21 Trailer Couplings. 22 Headlights. 23 Vehicle Appearance and Care. 24 Pre- and Post-Trip Checklists. 25 Pre- and Post-Trip Inspections and Maintenance. 26 In An Emergency.

It started out with the SPN 3364 FMI 2 (bad DEF quality, conversion low) and associated derate codes. I ran a regen or two, and the SPN 3364 cleared. But the SPN 5246 derate codes are still there! ... Adding Bunk windows to cascadia HaulingVibeZ posted Mar 28, 2024. 04 Freightliner ABS valve leaking ... > Commercial Truck Forums > Freightliner ...CASCADIA MAINTENANCE MANUAL Models: CA113DC CA113SLP CA125DC CA125SLP STI-478-6 (02/03/2022) Published by Daimler Truck North America LLC 4747 N. Channel Ave. Portland, OR 97217 ... Freightliner Dealership has the qualified technicians and equipment to perform this maintenance for you. They canIn most cases, the "Manual Regeneration Not Allowed" will appear after your vehicle has asked you several times to turn on the manual regen mode. Very often, this happens after your truck idles for an extended period. For example, you may have stopped to sleep in a very cold place and don't want to turn off the engine.The fault indicates that the High Idle Regeneration (HIR) was aborted due to the Diesel Oxidation Catalyst (DOC) inlet temperature not reaching the minimum of 270°C (518°F) to initiate dosing during an HIR. The CEL and MIL lamps will remain ON until the fault is resolved or a successful regeneration is completed. Show/Hide Checkboxes.Freightliner Cascadia Regen Problems. If you're having regen problems on your freightliner, there are two ways to fix it. One is to use active regeneration, which cleans the DPF while the vehicle is in motion. If you're having trouble with active regeneration, you can try parked regeneration. To do this, shift your transmission from neutral to ...Hi, why DEF light blinking on Freightliner tank is full? Though the DEF light blinks mainly when the DEF tank is empty or nearly empty, if the tank is full, ...Jan 23, 2018 · Freightliner cascadia EPA10 does not do regen. It is in regen zone 2. I started regen. Regen started. DOC inlet go to 750 and both others are around 750 as well. But diagnostic link never shows that r … read more Please support our sponsors and let them know you heard about their products on iRV2. Thread Tools. 01-26-2023, 10:01 AM. Porcineman. Junior Member. Join Date: Jan 2023. Location: Cincinnato. Posts: 3. 2023 Freightliner Cascadia fast idle.

Yeah, that's a regen. I have that kind of truck and when i use opti idle it has 2 higher rev moments, one where it goes just below 10 on the rpms which i've been told it does to charge batteries faster and then a different one where it goes above 10 which I believe is a regen. regens suck : (.2016 Freightliner Conventional - Sleeper Trucks For Sale: 212 Trucks Near Me - Find New and Used 2016 Freightliner Conventional - Sleeper Trucks on Commercial Truck Trader. ... (115) CASCADIA 125 (31) CASCADIA (16) CASCADIA EVOLUTION (12) CASCADIA 113 (10) CASCADIA DD13 (6) CORONADO (4) 122 SD (3) BUSINESS CLASS M2 106 (1) 114 SD.A regen (parked or not) should take no longer than 45 minutes- This sounds very similar to what mine did. During regeneration, check the exhaust temp- it should be around 1000-1100 degrees. ... 2015 Cascadia Autoshift points Freightisgreat posted May 2, 2024 at 5:19 PM. Rocker arm. Mr Bob posted May 2, 2024 at 3:37 PM. Air conditioning …After exhaust gasses leave the engine, they flow into the ATS. First they flow into a two-part ATD, comprised of a diesel oxidation catalyst (DOC), and a diesel particulate filter (DPF). The DPF traps soot particles, then exhaust heat converts the soot to ash in the DPF, in a process called regeneration (regen).Instagram:https://instagram. is atz lee still marriedelements of modernism mastery testdewitt county sheriff ilhow to reset descale button on keurig second opinion] Hello sir, I have freightliner Cascadia 2018. My truck does parked Regen every day and only 15 minutes ... just had the dpf and doc out of a freightliner Cascadia cleaned. after it was reinstalled I ran the regen to clear active codes. now it's throwing code 1664 and shutting down the regen. i'm just tryin ...This fix needs you to follow a series of steps in the proper sequence. The first thing to do is to pull the parking brake. You then put your transmission gear in neutral and then put it back slowly into drive while holding your parking brake. This fix should solve the problem and get your truck back to its activities. lake winnebago water conditionsastro command center not detecting a40 mixamp I have a freightliner Cascadia 2015 and I have the yellow engine light on, yellow check engine light on and for def I have the yellow blinking light by the gage and I can not go faster than 55 mi/h ... having issues with 2015 cascadia dd15 engine regen issues vin 3AKJGLD57FSGB4103 these are the fault codes, 4364 fmi 1, 4364 fmi 18, 3364 fmi 2 ...One of the most common ones is to perform a parked regeneration. But parked regens do not always go as easy as pull over, push the button and voilà...regen. In this blog we are … hydrocodone blue pill The engine keeps on idling to warm up the cabin for 8 hours. Chances are that within this time the Freightliner will ask for manual regeneration because the DPF may get clogged when the vehicle is idling. If you don't turn on the manual regen just because you are sleeping, the vehicle will shut off or keep idling until the DPF is overly clogged.Sep 15, 2023 · Mechanic's Assistant: Im sorry to hear about the issues youre experiencing with your 2017 Freightliner Cascadia, but Im confident that the truck Mechanic will be able to help you resolve the regen and engine light concerns youre facing. Have you checked the DEF fluid level in your 2016 Freightliner Cascadia? Yes I have 58 %